Table VIII. Comparison of emissions from selected residential space heating, power generation, and transportation sources
Source |
CO
lb/106 Btu
|
NOx(as NO2)
lb/106 Btu
|
SOx(as SO2)
lb/106 Btu |
B(a)P
ug/106 Btu |
Particulates
lb/106 Btu |
Residential Space Heating |
|
|
|
|
|
Gas |
0.02a |
0.08a |
0.0006a |
80c |
0.02a |
Oil |
0.04a |
0.09a |
0.3- 7ab |
900c |
0.07a |
Coal |
3.5a |
0.1a |
0.5-7ab |
2,500,000c |
0.6a |
Wood: Fireplace |
3.0d |
0.25d |
|
45,000d |
1.3d |
Wood: Stove |
22d |
0.07d |
0.03d |
135,000d |
1.2d |
Power Generation |
|
|
|
|
|
Coal |
|
|
|
(20 - 400)c |
|
Transportation (lb/50 mi) |
lb/50 mi |
lb/50mi |
lb/50 mi |
ug/50 mi |
lb/50 mi |
Highway vehicles |
2.4a |
0.34a |
0.02a |
50c |
0.06a |
a Reference 54.
b Takes into account sulfur variability in the fuel.
c Reference 31, page 23.
d From Table VI.
|